Regular inspections aren't optional — they're required by code. We do them right and give you the documentation you need.

  • Kansas requires annual fire sprinkler inspections under NFPA 25 — quarterly for some system types
  • Myers AFP inspects all system types statewide, including fire pumps and backflow devices
  • 24/7 availability — call (316) 833-3215 to schedule

If your system hasn't been inspected this year, you're already behind

NFPA 25 requires fire sprinkler systems to be inspected, tested, and maintained on a regular schedule. Most commercial property owners know about the annual inspection — but there are also quarterly requirements, and a comprehensive 5-year inspection that most people miss until the fire marshal catches it.

We perform NFPA 25 inspections at all required intervals with fast turnarounds on reporting and direct upload to AHJ databases. You'll have your documentation when you need it.

We serve commercial buildings, multi-family housing, industrial facilities, and residential properties across Kansas and Northern Oklahoma.

Fire sprinkler riser manifold with control valves and gauges inspected at a Kansas commercial facility

NFPA 25 Inspection Schedule

Weekly
  • Control valve positions
  • Gauges on pre-action and dry systems
Monthly
  • Wet system gauges
  • Alarm valve condition
  • Waterflow alarm devices
Quarterly
  • Alarm devices
  • Control valves
  • Fire department connections
  • Hydraulic nameplates
Annually
  • Full system inspection per NFPA 25
  • Flow testing documentation
  • Obstruction investigation where required
  • Antifreeze concentration check
Every 5 Years
  • Internal pipe inspection
  • Obstruction investigation
  • Gauge replacement
  • Sprinkler head sample testing

What every inspection includes

Every inspection is documented and reported. No verbal-only assessments.

Full visual inspection of all sprinkler heads
Control valve testing and documentation
Alarm and waterflow device testing
Fire department connection condition
Gauge accuracy verification
Hanger and brace inspection
Written deficiency report
Compliance documentation for your records
Clear timeline for any required corrections

Also part of NFPA 25 compliance

Full NFPA 25 compliance isn't just about the sprinkler heads. If your system has a fire pump or a backflow preventer, those need to be tested too.

Fire Pump Testing

Annual and monthly flow tests per NFPA 25. We document performance and report deficiencies.

Learn more →

Backflow Device Testing

Annual certification required on backflow preventers in fire protection systems. We test, document, and certify.

Learn more →